Bottom price Laminated Bus Bar Manufacturers - DF205 Modified Melamine Glass Cloth Rigid Laminated Sheet – D&F
Bottom price Laminated Bus Bar Manufacturers - DF205 Modified Melamine Glass Cloth Rigid Laminated Sheet – D&F Detail:
DF205 Modified Melamine Glass Cloth Rigid Laminated Sheet consists of woven glass cloth impregnated and bonded with a melamine thermosetting resin, laminated under high temperature and high pressure. The woven glass cloth shall be alkali-free.
With a high mechanical and dielectric properties and excellent arc resistance, the sheet is intended for electrical equipment as insulation structural parts, where high arc resistance is required. It also passed toxic and hazardous substance detection (RoHS Report). It is equivalent to NEMA G5 sheet, MFGC201, Hgw2272.
Available thickness: 0.5mm~100mm
Available sheet size:
1500mm*3000mm、1220mm*3000mm、1020mm*2040mm,1220mm*2440mm、1000mm*2000mm and other negotiated sizes.
The Nominal Thickness And Allowed Tolerance (mm)
Nominal thickness | Deviation | Nominal thickness | Deviation | Nominal thickness | Deviation |
0.5 | +/-0.15 | 3 | +/-0.37 | 16 | +/-1.12 |
0.6 | +/-0.15 | 4 | +/-0.45 | 20 | +/-1.30 |
0.8 | +/-0.18 | 5 | +/-0.52 | 25 | +/-1.50 |
1 | +/-0.18 | 6 | +/-0.60 | 30 | +/-1.70 |
1.2 | +/-0.21 | 8 | +/-0.72 | 35 | +/-1.95 |
1.5 | +/-0.25 | 10 | +/-0.94 | 40 | +/-2.10 |
2 | +/-0.30 | 12 | +/-0.94 | 45 | +/-2.45 |
2.5 | +/-0.33 | 14 | +/-1.02 | 50 |
Bending Deflection for Sheets (mm)
Thickness |
Bending deflection |
|
1000(Ruler length) |
500(Ruler length) |
|
3.0~6.0 |
≤10 |
≤2.5 |
6.1~8.0 |
≤8 |
≤2.0 |
>8.0 |
≤6 |
≤1.5 |
Mechanical Processing
The sheets shall be free of cracks and scraps after being machined (punching & shearing).
Physical, Mechanical And Dielectric Properties
No. | Properties | Unit | Standard value | Typical value | ||
1 | Density | g/cm3 | 1.90~2.0 | 1.95 | ||
2 | Water absorption(3mm) | mg | See the following table | 5.7 | ||
3 | Flexural strength, perpendicular to laminations (Lengthwise) | At normal condition | MPa | ≥270 | 471 | |
4 | Impact strength(Charpy, notch, lengthwise) | kJ/m2 | ≥37 | 66 | ||
5 | Tensile strength | MPa | ≥150 | 325 | ||
6 | Compressive strength | MPa | ≥200 | 309 | ||
7 | Adhesive/bond strength | N | ≥2000 | 4608 | ||
8 | Shear strength, parallel to laminations | MPa | ≥30 | 33.8 | ||
9 | Dielectric Strength,perpendicular to laminations ( in transformer oil at 90℃+/-2℃) | MV/m | ≥14.2 | 20.4 | ||
10 | Breakdown voltage,parallel to laminations (in transformer oil at 90℃+/-2℃) | kV | ≥30 | 45 | ||
11 | Insulation resistance, parallel to laminations | At normal condition | Ω | ≥1.0 x 1010 | 4.7 x 1014 | |
After 24h in water | ≥1.0 x 106 | 2.9 x 1014 | ||||
12 | Dielectric dissipation factor 1MHz | – | ≤0.02 | 0.015 | ||
13 | Dielectric constant 1MHz | – | ≤5.5 | 4.64 | ||
14 | Arc resistance | s | ≥180 | 184 | ||
15 | Tracking resistance | PTI | V | ≥500 | PTI500 | |
CTI | ≥500 | CTI600 | ||||
16 | Flammability | Grade | V-0 | V-0 |
Water Absorption
Average thickness of test samples (mm) |
Water absorption (mg) |
Average thickness of test samples (mm)
|
Water absorption (mg) |
Average thickness of test samples (mm)
|
Water absorption (mg) |
0.5 |
≤17 |
2.5 |
≤21 |
12 |
≤38 |
0.8 |
≤18 |
3.0 |
≤22 |
16 |
≤46 |
1.0 |
≤18 |
5.0 |
≤25 |
20 |
≤52 |
1.6 |
≤19 |
8.0 |
≤31 |
25 |
≤61 |
2.0 |
≤20 |
10 |
≤34 |
For sheet thicker than 25mm,it shall be machined to 22.5mm on one side. |
≤73 |
Remarks:1 Remarks: If the caculated average of measured thickness is between two thcikness mentioned in this table, the values will be acuired by interpolation. If the caculated average of measured thickness is less 0.5mm, the vales will not be over 17mg. If the caculated average of measured thickness is over 25mm, the value will not be over 61mg.2 .If nominal thciness is more than 25mm,it shall be machined to 22.5mm on one side only. The machined side should be smooth. |
Packing And Storage
The sheets shall be stored in a place where temperature is no higher than 40℃, and be placed horizontally on a bedplate with a height of 50mm or above. Keep away from fire, heat (heating apparatus) and direct sunshine. The storage life of sheets is 18 months from the date of leaving factory. If the storage duration is over 18 months, the product also could be used after being tested to be qualified.
Remarks and Precautions for Application
1 A high speed and small cutting depth shall be applied when machining because of sheets’ weak thermal conductivity.
2 Machining and cutting this product will release much dust and smoke. Suitable measures should be taken to ensure dust levels are within acceptable limits during operations. Local exhaust ventilation and using the suitable dust/particle masks are advised.
3 The sheets are subject to moisture after being machined, a coating of insulating vanish is recommended.
Production Equipment
The Package For Laminated Sheets
Product detail pictures:
Related Product Guide:
Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of employees building, striving hard to boost the standard and liability consciousness of staff members. Our corporation successfully attained IS9001 Certification and European CE Certification of Bottom price Laminated Bus Bar Manufacturers - DF205 Modified Melamine Glass Cloth Rigid Laminated Sheet – D&F , The product will supply to all over the world, such as: Czech Republic, Leicester, Poland, We have advanced production technology, and pursuit innovative in goods. At the same time, the good service has enhanced the good reputation. We believe that as long as you understand our product, you need to be willing to become partners with us. Looking forward to your inquiry.
By Kitty from Islamabad - 2017.09.09 10:18
The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
By Kitty from British - 2018.12.22 12:52